Araldite ® Tarepoxy 036 TU


PITCH EXTENDED EPOXY RESIN
 
USES
Heavy duty protective coating for sewage pipes, water pipes, dams, locks, canal walls, bridges and any area requiring a high degree of protection from an aggressive environment.

SPECIAL FEATURES
* SOLVENT FREE
* POSITIVE ADHESION TO CONCRETE AND STEEL
* GOOD CHEMICAL RESISTANCE

DESCRIPTION
Araldite Tar Epoxy 036 TU is a two-component pitch extended epoxy coating based on Araldite epoxy resins. Each component is factory weighed and packaged ready for on site mixing

PHYSICAL PROPERTIES
 Time at
 20° C30° C40° C
Pot life
Initial Hardness
Recoating interval
Full cure
100 min
19hrs.
12-40h.
7 days
70 min
10hrs.
8-20 h.
7 days
30 min
6 hrs.
5-1 5 h.
7 days

CHEMICAL PROPERTIES
Araldite Tar Epoxy 036 TU shows excellent resistance to:
Tap Water
Sea Water
Brine
Crude oil
Dilute Acids
Dilute alkalis

CAUTION
Keep uncured epoxy materials away from the mouth, food or drink.
Do not use empty tins to store food even if they appear to have been cleaned.
Always wear gloves or barrier cream when handling uncured epoxy materials. Clean any splashes or smears from the skin immediately
using warm water and soap.
Avoid inhaling vapour.
Do not use below 5B C.

NOTICE
The information in this publication, given in good faith, is based on the present state of our knowledge but all recommendations are made without guarantee since the conditions of use are beyond our control. Buyers and users should make their own assessment of our products under their own conditions and for their own requirements.



 

INSTRUCTIONS FOR USE
PREPARATION

New concrete should be at least 28 days old when the moisture content of the surface should be less than 5 %. All laitence and loose material must be removed from the concrete surface. If the concrete is sound and strong with light laitence this can be achieved with acid etching followed by thorough washing with water. The floor must then be left to dry.
Cracked or damaged concrete or heavy laitence should be prepared by grit blasting or scarifying until a solid surface is reached showing exposed
aggregate. The surface should then be leveled using Araldite Hole Filler.
Surfaces contaminated with oil or grease should be flame cleaned or thoroughly washed with a good detergent then rinsed and left to dry.
Steel surfaces must be shot blasted to Swedish standard SA 2 ½ . The coating should then be applied before further corrosion can begin.

MIXING
Mechanical mixing of resin based materials is preferred whenever possible. In order to avoid trapping air in the material, mixers running at less than 600 rpm are recommended.

APPLICATION
Araldite Tar Epoxy 036 TU is supplied as two preweighed packs in exact proportions. No other materials should be added.
STIR CONTENTS OF EACH TIN THOROUGHLY. Pour the entire contents of the hardener into the resin and mix until uniform. Using a brush, roller or airless spray apply about 300 grams of mix per square meter of substrate. This is equivalent to a film of approx. 240 microns thick. Apply a second coating within the stated re-coating interval to achieve fullest possible protection. If a longer period is left between coatings then intercoat adhesion may be impaired.

CURING
The coating will be touch dry within the initial hardness time. Contact with aggressive chemicals should not be allowed until after full cure.

CLEANING DOWN
Use HUntsman Cleaning Fluid.

COVERAGE
Araldite Tar Epoxy 036 TU

10 kg pack covers 33 m2 at 300g/m2 (single coat)

STORAGE
Shelf life of 12 months minimum if stored below 25Q C.