Araldite ® Primer 011



KiMYASAL ÖZELLİKLER
Araldite Epoxycoat T.L. 20° C'de 12 ay sureyle aşağıdaki maddelere daldırılarak test edilmiş ve etkilenmemiştir.
Deniz suyu
Sülfirik asit % 10
Sülfirik asit % 30
Hidroklorik asit % 10
Hidroklorik asit % 20
Kostik soda % 10
Kostik soda % 30
Amonyak % 10
Amonyak % 25
Asetik asit % 10
Asetik asit % 50
Laktik asit % 10
Keten tohumu yağ asidi
Tal yağı asidi
Ksilen
Benzin
Ham petrol

Pürüzlü beton yüzeylerde sarfiyat daha fazla olacaktır. Kaplama, tam kuruma suresi tamamlanmadan, kimyevi maddelerle temas etmemelidir.

TEMİZLEME
Vantico Cleaning Fluid kullanınız.

VERİM
Araldite Epoxycoat T.L.: 10 kg'lık paketlerde bulunan malzemenin sarfiyatı yaklaşık 1 kg/m2 olacaktır. Pürüzlü yüzeyler için daha fazla malzeme gerekebilir.


LIQUID EPOXY RESIN FOR TANK LINING
 
USES
A coating used in the re bottoming and repair of corroded crude oil storage and ballast tanks. When used as part of a laminating system a badly corroded tank bottom may be restored to a working condition, which will resist further corrosion

SPECIAL FEATURES
* SOLVENT FREE
* COST EFFECTIVE
* PREVENTS FURTHER CORROSION
* RAPID
* FACTORY PRE-WEIGHED COMPONENTS

DESCRIPTION
Araldite Epoxycoat T.L. is a two component solvent free clear epoxy coating based on Araldite epoxy resin.
Each component is factory weighed and packaged ready for on site mixing

PHYSICAL PROPERTIES
Temperature20s C 40s C
Relative humidity65%65%
Pot life
Re-coating time
Initial hardness
Full cure
5-7 hours
20-40 hours.
30 hours
days
2-3 hours
7-15 hours.
12 hours
4 days

CHEMICAL PROPERTIES
Samples of Araldite Epoxycoat T.L. were submerged in test reagents for 12 months at 20s C. The samples were unaffected by the following chemicals:
Sea water
Sulphuric acid 10%
Sulphuric acid 30 %
Sulphuric acid 70 %
Hydrochloric acid 10 %
Hydrochloric acid 20 %
Caustic soda 10 %
Caustic soda 30 %
Ammonia 10%
Ammonia 25 %
Acetic acid 10 %
Acetic acid 50 %
Lactic acid 10 %
Linseed oil fatty acid
Tall oil fatty acid
Xylene
Gasoline
Crude oil

CAUTION
Keep uncured epoxy materials away from the mouth, food or drink.
Do not use empty tins to store food even if they appear to have been cleaned.
Always wear gloves or barrier cream when handling uncured epoxy materials. Clean any splashes or smears from the skin immediately using warm water and soap.
Avoid inhaling vapour.
Do not use below 59 C.

NOTICE
The information in this publication, given in good faith, is based on the present state of our knowledge but all recommendations are made without guarantee since the conditions of use are beyond our control. Buyers and users should make their own assessment of our products under their own conditions and for their own requirements.


 

INSTRUCTIONS FOR USE
PREPARATION

Steel must be cleaned and prepared to Swedish standard SA 21/2. Araldite Steel Primer 012 should then be applied at no more than 30 microns thick. Any sharp edges must be smoothed and corners filled with a putty of Araldite Epoxycoat T.L. plus silica flour.

MIXING
Mechanical mixing of resin based materials is to be preferred. Mixers running at less than 400 rpm are recommended.

APPLICATION
Araldite Epoxycoat T.L. is supplied as two pre weighed packs in exact proportions. No other materials should be added. STIR CONTENTS OF EACH TIN THOROUGHLY Pour the entire contents of the hardener into the resin and mix until clear and uniform. Avoid entraining air. Apply to the primed surface by roller and begin applying glass mat immediately, working the wet resin through the glass mat. Immediately apply successive layers of resin glass mat ending with a finishing tissue and leave to harden. Finally apply an abundant surface coat within the stated recoating time. If not intercoat adhesion will be impaired.


CURING
Allow the laminated tank to reach full cure before refilling.

CLEANING DOWN
Use Huntsman Cleaning Fluid to clean tools only outside the tank in well ventilated areas.
Do not use cleaning fluid on the skin.

COVERAGE
Araldite Epoxycoat T.L.

10 kg. pack covers 10m2 built up in several layers.

STORAGE
Shelf life of 12 months minimum if stored below 25° C.